Papers — Biweekly Series

Functional safety research, in the form the academy expects.

Every two weeks, a Field Notes thread is deepened with academic sources and rendered as an IEEE-format paper. PDFs are downloadable; the inline viewer below mirrors the two-column layout. Citations follow IEEE numeric style.

All Papers

Volume 01

October 15, 20267 pages

When the Fix Stops at the Program Boundary: An Inheritance-Graph Framework for Bounding Sibling Exposure After a Confirmed Safety Anomaly in ISO 26262 Field Monitoring

An inheritance-graph framework that prices the exposure accumulated while a sibling vehicle program awaits evaluation after a confirmed safety anomaly. Six relations give transfer probability, exposure, break-even event rate and maximum decision latency. Applied to the Hyundai Palisade and Ioniq 9 seat recalls and the Ram ProMaster scope extension.

Read paper
October 1, 20269 pages

When Stopping Is Falling: A Safe-State Reachability Framework for Protective-Stop Design in Dynamically Stable Industrial Robots

A safe-state reachability framework for legged robots, where de-energization is a fall rather than a stop. A four-rung safe-state ladder and eight relations show that seat-on-approach multiplies reach-failure probability by the person-approach rate, exceeding the PL d budget by four orders of magnitude, and that the seated descent belongs to de-energization, not proximity response.

Read paper
September 15, 20268 pages

When the Safe State Is the Payoff: A Demand-Origin Framework for Bounding Adversary-Selected Spurious Activation of Safety-Instrumented Functions

A demand-origin partition that separates genuine demand, random spurious activation, and adversary-commandable spurious activation of a safety-instrumented function. Five relations show that the commandable component is bounded by no reliability parameter, that its cut order equals the voting threshold, that adversarial timing amplifies consequence, and that the restoration interval enters PFD directly. Demonstrated on the Rockwell Logix CIP fault advisory (ICSA-26-244-03), where one induced fault per year consumes 91 percent of the SIL 3 budget.

Read paper
September 1, 20269 pages

Corroboration Is Not Authentication: Bounding the Receiver-Side Integrity Assurance Available to Unauthenticatable Cooperative Datalinks in Aviation and Maritime Transport

A framework that treats receiver-side plausibility checking as an allocatable safety mechanism with a measurable coverage ceiling. Five relations show that against an adaptive adversary only channels outside the attacker’s write authority contribute assurance, and only if their verdict precedes irreversible commitment. Demonstrated on CISA ICSA-26-219-01 (CPDLC over ATN-B1) and ICSA-26-237-07 (FURUNO FA-50 AIS), both of which close with no mitigation available.

Read paper
August 15, 20269 pages

When Every Recall Has a New Root Cause: A Mechanism-Novelty Estimator for Requirement-Level Recurrence in Automotive Safety Compliance

A framework that reads a requirement's recurrence record as one verification signal rather than a series of defect signals. Good-Turing missing mass and a bias-corrected Chao bound separate novelty-dominated recurrence, which indicts verification coverage, from repeat-dominated recurrence, which indicts corrective-action effectiveness. Demonstrated on Ford's five-action FMVSS 111 series.

Read paper
August 1, 202610 pages

Detection Is Not a Device Property: A Sensing-Envelope and Responder-Conditioned Framework for Risk-Control Verification in Life-Sustaining Medical Devices

A six-step framework that bounds the detectability of a credited ISO 14971 risk control by the device's physical sensing envelope, and bounds the efficacy of a life-withholding safe state by the availability of an external responder. Demonstrated on the July 2026 Omnipod cannula-tear Class I recall, where an open-path leak moves the pressure surrogate toward the healthy reading, and the ResMed Astral Early Alert, where the fail-safe state stops life-support ventilation.

Read paper
July 15, 20267 pages

When the Credited Mechanism Is Off Duty: A State-Indexed Availability Framework for Safety-Mechanism Claims in ISO 26262 Safety Cases

A six-step framework that indexes every credited ISO 26262 safety mechanism by vehicle operating state, exposing availability gaps where the hazard is active but the mechanism is asleep, absent, or unpowered. Demonstrated on the 2026 Ford park-by-wire rollaway recall (26V402), whose EPB rollaway detection may sleep with the PCM, and the Volkswagen ID.4 recall (26V030), whose Self-Discharge Detection was never installed.

Read paper
July 1, 20267 pages

Bounding the Latent-Failure Exposure of Defeated Monitors: A Quantitative Certification-Maintenance-Requirement Framework for Dormant Protective Functions in Transport-Category Aircraft

A six-step framework that turns airworthiness-directive evidence of defeated dormant monitors into a derived Certification Maintenance Requirement interval plus independence and non-perturbation requirements. Demonstrated on the 2026 Boeing 737NG thrust-reverser lock-indication AD and the ATR 42 flap-asymmetry detector AD, showing that when a maintenance-defeat term dominates, no achievable inspection interval restores the 14 CFR 25.1309 budget.

Read paper
June 17, 20266 pages

From Public-Demo Incident to Bystander-Safety Contract: A Cross-Standards Framework for Speed-and-Separation and Power-and-Force Requirement Derivation in Untethered Humanoid Robots

A six-step cross-standards framework that translates 2026 public humanoid-robot contact incidents — most prominently the Unitree G1 roundhouse-kick strike on a child in Urumqi — into ISO/TS 15066 power-and-force limits, ISO 13855 separation distances, and ISO 10218-2 / ISO 13849-1 PL d protective-stop requirements, with two equations, a fault tree, and five derived requirements.

Read paper
June 1, 20269 pages

From Vendor SBOM Gap to SIS Independence Violation: A Cross-Standards Framework for Translating OT Cybersecurity Field Evidence into IEC 62443-4-1, IEC 62443-3-3, and IEC 61511 Requirements

A six-step cross-standards framework that translates two 2026 OT cybersecurity field events — the Siemens SENTRON 7KT request-smuggling defect (CVE-2025-22871, CISA ICSA-26-134-14) and the CyberAv3ngers PLC compromise campaign (CISA AA26-097A) — into IEC 62443-4-1 secure-development residuals, IEC 62443-3-3 zone-and-conduit controls, and IEC 61511 safety-instrumented-system independence requirements.

Read paper
May 16, 20268 pages

From Functional Insufficiency to Behavior-Policy Gate: A Cross-Standards Framework for ODD Boundary Enforcement in Level-4 Robotaxis under Degraded Environmental Conditions

A six-step cross-standards framework that translates degraded-environment perception evidence into ISO 21448 triggering conditions, UL 4600 claim-based gates, and ISO 26262 minimal-risk-condition contracts for SAE Level-4 robotaxis. Demonstrated on the May 2026 Waymo San Antonio flood-traversal recall and the March 2026 NHTSA EA26002 escalation of Tesla Full Self-Driving in reduced-visibility crashes.

Read paper
May 10, 20268 pages

Reframing Latent Software Anomalies in Class C Infusion Pumps: A Cross-Standards Framework Bridging IEC 62304, ISO 14971, and IEC 60601-1-8

A six-step cross-standards framework that translates two latent software anomalies — silent battery-state misreporting and a numeric-input fail-stop — into IEC 62304 unit-verification residuals, ISO 14971 risk-control measures, and IEC 60601-1-8 alarm-conformance assertions. Demonstrated on the February 2026 Fresenius Kabi Ivenix LVP Class I recall, with a corrected severity argued to be Catastrophic.

Read paper
May 9, 20266 pages

Hazard Assessment for Autonomous eVTOL Perception in Degraded Visual Environments: A Cross-Standards Framework Bridging ARP4761A, DO-178C/254, and Automotive ADAS Field Evidence

A six-step cross-standards framework that translates perception-availability evidence into ARP4761A FHA, FDAL/IDAL, and ASTM F3269-21 Run-Time Assurance artifacts for SC-VTOL-01 Category Enhanced eVTOL. Demonstrated on the NHTSA EA26002 escalation of automotive Full Self-Driving in degraded visual environments and the NTSB Joby JAS4-2 final report.

Read paper